Winsen Battery Leak Detection Module ZE21-CS

Ask Our AI Assistant

Product Image
Working Principle

Description

The Winsen Battery Leak Detection Module ZE21-CS utilizes the electrochemical principle to detect volatile gases from battery liquid and gases generated when the battery burns. It features high selectivity and stability due to its specialized sensor design. The module includes a built-in temperature sensor for temperature compensation.

Sensor Types

Electrochemical

Dos And Donts

Donts

  • Expose To High Humidity: Avoid using the sensor in environments where humidity exceeds 90% RH to prevent condensation issues.,
  • Use Near Strong Interferents: Keep the sensor away from significant sources of alcohol and other interfering gases to maintain accuracy.

Dos

  • Ensure Proper Ventilation: Install the sensor in areas with adequate airflow to ensure accurate gas detection.,
  • Follow Voltage Guidelines: Operate the sensor within the recommended voltage range of 5~10V DC to prevent damage.,
  • Preheat The Sensor: Allow the sensor a preheat time of 40 seconds before expecting reliable readings.
Limits

Gas Detection Range

0 to 1000ppm

Humidity Range

15%RH to 90%RH (No condensation)

Resolution

1ppm

Temperature Range

  • Operating: -20°C to 65°C,
  • Storage: -30°C to 65°C
How To Connect

Uart Interface

  • Description: Connect the sensor's UART output (3.3V TTL) to a compatible microcontroller or computer interface for digital communication.,
  • Connection Tip: Ensure the logic levels match the device to which the sensor is being connected to avoid data corruption.
Dimensions

Module Size

7 × 4 × 2 cm

Shipping Weight

0.01 kg